Technical Specifications

Maximum flow [l/min]
466,60
Maximum head [m]
71,80
Input voltage [V]
3x400
Power output - P2 [kW]
2,20

Show all Tech Specs

on demand check availability

Goods cannot be purchased online. These are either oversized goods with an individual price of transport or an assortment that can only be purchased on demand. If you are interested in the goods, contact us by email marketing@pumpa.cz

6,602.83 VAT included

Not sellable online

Delivery accross EU within 2-4 days %

Brand:
PUMPA
Category:
Pressure booster sets - horizontal
Product No.:
ZB00064933
Sale group:
ATSP
EAN:
8596455035534

Product variants

  • Technical Specifications
  • Product No.
  • Maximum flow [l/min]
  • Maximum head [m]
  • Input voltage [V]
  • Power output - P2 [kW]
  • Suction port ["]
  • Delivery port ["]
  • Maximum suction lift [m]
  • Drinking water certificate
  • Vessel volume [l]
  • Maximum current [A]
  • Maximum liquid temperature [°C]
  • Protection [IP]
  • Dry run protection
  • Off switch
  • Speed ​​control
  • Pump design
  • Impeller material
  • Availability
  • Price

next

Variant Product No.

Availability

Price (VAT incl.)

Maximum flow [l/min]
150
Maximum head [m]
65,10
Input voltage [V]
3x400
Power output - P2 [kW]
1,10
Suction port ["]
5/4
Delivery port ["]
1
Maximum suction lift [m]
8
Drinking water certificate
YES
Vessel volume [l]
2x24
Maximum current [A]
1,90
Maximum liquid temperature [°C]
60
Protection [IP]
55
Dry run protection
NO
Off switch
YES
Speed ​​control
YES
Pump design
horizontal
Impeller material
stainless steel
Maximum flow [l/min]
233,40
Maximum head [m]
34,80
Input voltage [V]
3x400
Power output - P2 [kW]
0,75
Suction port ["]
5/4
Delivery port ["]
1
Maximum suction lift [m]
8
Drinking water certificate
YES
Vessel volume [l]
2x24
Maximum current [A]
1,40
Maximum liquid temperature [°C]
60
Protection [IP]
55
Dry run protection
NO
Off switch
YES
Speed ​​control
YES
Pump design
horizontal
Impeller material
stainless steel
Maximum flow [l/min]
233,40
Input voltage [V]
3x400
Delivery port ["]
1
Maximum suction lift [m]
8
Drinking water certificate
YES
Vessel volume [l]
2x24
Maximum liquid temperature [°C]
60
Protection [IP]
55
Dry run protection
NO
Off switch
YES
Speed ​​control
YES
Pump design
horizontal
Impeller material
stainless steel
Maximum flow [l/min]
233,40
Maximum head [m]
80,70
Input voltage [V]
3x400
Power output - P2 [kW]
1,50
Suction port ["]
2
Delivery port ["]
6/4
Maximum suction lift [m]
8
Drinking water certificate
YES
Vessel volume [l]
2x24
Maximum current [A]
3,20
Maximum liquid temperature [°C]
60
Protection [IP]
55
Dry run protection
NO
Off switch
YES
Speed ​​control
YES
Pump design
horizontal
Impeller material
stainless steel
Maximum flow [l/min]
233,40
Maximum head [m]
93,90
Input voltage [V]
3x400
Power output - P2 [kW]
2,20
Suction port ["]
2 1/2
Delivery port ["]
6/4
Maximum suction lift [m]
8
Drinking water certificate
YES
Vessel volume [l]
2x24
Maximum current [A]
3,90
Maximum liquid temperature [°C]
60
Protection [IP]
55
Dry run protection
NO
Off switch
YES
Speed ​​control
YES
Pump design
horizontal
Impeller material
stainless steel
Maximum flow [l/min]
466,60
Maximum head [m]
71,80
Input voltage [V]
3x400
Power output - P2 [kW]
2,20
Suction port ["]
2 1/2
Delivery port ["]
2
Maximum suction lift [m]
8
Drinking water certificate
YES
Vessel volume [l]
2x24
Maximum current [A]
4,70
Maximum liquid temperature [°C]
60
Protection [IP]
55
Dry run protection
NO
Off switch
YES
Speed ​​control
YES
Pump design
horizontal
Impeller material
stainless steel
You are viewing this variant
Maximum flow [l/min]
466,60
Maximum head [m]
96
Input voltage [V]
3x400
Power output - P2 [kW]
3
Suction port ["]
2 1/2
Delivery port ["]
2
Maximum suction lift [m]
8
Drinking water certificate
YES
Vessel volume [l]
2x24
Maximum current [A]
6
Maximum liquid temperature [°C]
60
Protection [IP]
55
Dry run protection
NO
Off switch
YES
Speed ​​control
YES
Pump design
horizontal
Impeller material
stainless steel
Maximum flow [l/min]
800
Maximum head [m]
57,90
Input voltage [V]
3x400
Power output - P2 [kW]
3
Suction port ["]
3
Delivery port ["]
2 1/2
Maximum suction lift [m]
8
Drinking water certificate
YES
Vessel volume [l]
2x24
Maximum current [A]
5,70
Maximum liquid temperature [°C]
60
Protection [IP]
55
Dry run protection
NO
Off switch
YES
Speed ​​control
YES
Pump design
horizontal
Impeller material
stainless steel
Maximum flow [l/min]
800
Maximum head [m]
101,90
Input voltage [V]
3x400
Power output - P2 [kW]
5,50
Suction port ["]
3
Delivery port ["]
2 1/2
Maximum suction lift [m]
8
Drinking water certificate
YES
Vessel volume [l]
2x24
Maximum current [A]
10,30
Maximum liquid temperature [°C]
60
Protection [IP]
55
Dry run protection
NO
Off switch
YES
Speed ​​control
YES
Pump design
horizontal
Impeller material
stainless steel
Maximum flow [l/min]
933,40
Maximum head [m]
46,80
Input voltage [V]
3x400
Power output - P2 [kW]
3
Suction port ["]
3
Delivery port ["]
2 1/2
Maximum suction lift [m]
8
Drinking water certificate
YES
Vessel volume [l]
2x24
Maximum current [A]
5,90
Maximum liquid temperature [°C]
60
Protection [IP]
55
Dry run protection
NO
Off switch
YES
Speed ​​control
YES
Pump design
horizontal
Impeller material
stainless steel
Maximum flow [l/min]
933,40
Maximum head [m]
78,50
Input voltage [V]
3x400
Power output - P2 [kW]
5,50
Suction port ["]
3
Delivery port ["]
2 1/2
Maximum suction lift [m]
8
Drinking water certificate
YES
Vessel volume [l]
2x24
Maximum current [A]
10,30
Maximum liquid temperature [°C]
60
Protection [IP]
55
Dry run protection
NO
Off switch
YES
Speed ​​control
YES
Pump design
horizontal
Impeller material
stainless steel

Product description

Execution

The automatic pressure station contains 2 horizontal stainless steel centrifugal pumps connected in parallel. Each pump is equipped with a frequency converter, which is located on the motor. Structural components that are in contact with the pumped liquid are made of AISI 304 stainless steel.

  • Space-saving and compact design
  • A simple and reliable solution
  • Stainless steel centrifugal pump
  • Wide area of application
  • Certificate for drinking water

Advantages

  • ensuring the necessary amount of water at a constant pressure
  • frequency converters ensure complete protection and control of the ATS
  • space-saving and compact design
  • The ATS is equipped with one output relay that can be used for fault monitoring for each pump
  • the operating state of the automatic pressure station is displayed on the display of the frequency converter using code states
  • on the display of frequency converters it is possible to display the set pressure, frequency, current and current pressure

Technical Specifications

Maximum flow [l/min]
466,60
Maximum head [m]
71,80
Input voltage [V]
3x400
Power output - P2 [kW]
2,20
Suction port ["]
2 1/2
Delivery port ["]
2
Maximum suction lift [m]
8
Drinking water certificate
YES
Vessel volume [l]
2x24
Maximum current [A]
4,70
Maximum liquid temperature [°C]
60
Protection [IP]
55
Dry run protection
NO
Off switch
YES
Speed ​​control
YES
Pump design
horizontal
Impeller material
stainless steel