Calpeda MXV 100-65xx vertical IN-LINE segment pumps made of INOX steel

Calpeda MXV 100-65xx vertical IN-LINE segment pumps made of INOX steel

Vertical multistage pumps with suction and discharge ports of the same diameter. They are located in the same axis (in-line). Corrosion-resistant sliding bearings are lubricated with pumped liquid. Removal of the mechanical seal without the need to dismantle the engine (applies to MXV 50 and MXV 100 with engines with a power higher than 4 kW). The pump is equipped with an axial bearing and an enabling insert use of any standard engine in IM V1 design. See more

Technical Specifications

Maximum flow [l/min]
1,466
Maximum head [m]
38.90 - 227.70
Input voltage [V]
3x400
Power output - P2 [kW]
15 - 45

Show all Tech Specs

on demand check availability

from 4,557.93 VAT included

Choose variant

Delivery accross EU within 3-7 business days %

Brand:
CALPEDA
Category:
Vertical surface pumps
Product No.:
MAS001585

Product variants

  • Technical Specifications
  • Product No.
  • Maximum flow [l/min]
  • Maximum head [m]
  • Input voltage [V]
  • Power output - P2 [kW]
  • Suction port ["]
  • Delivery port ["]
  • Maximum suction lift [m]
  • Maximum current [A]
  • Maximum liquid temperature [°C]
  • Protection [IP]
  • Automatic thermal protection
  • Dry run protection
  • Off switch
  • Speed ​​control
  • Capacitor
  • Pump design
  • Impeller material
  • Construction
  • Availability
  • Price

next

Variant Product No.

Availability

Price (VAT incl.)

Maximum flow [l/min]
1,466
Maximum head [m]
59.30
Input voltage [V]
3x400
Power output - P2 [kW]
15
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
21.50
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
this variant suits your choice
Maximum flow [l/min]
1,466
Maximum head [m]
38.90
Input voltage [V]
3x400
Power output - P2 [kW]
15
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
14.30
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
this variant suits your choice
Maximum flow [l/min]
1,466
Maximum head [m]
89.60
Input voltage [V]
3x400
Power output - P2 [kW]
18.50
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
34
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
this variant suits your choice
Maximum flow [l/min]
1,466
Maximum head [m]
67.30
Input voltage [V]
3x400
Power output - P2 [kW]
15
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
27.30
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
this variant suits your choice
Maximum flow [l/min]
1,466
Maximum head [m]
111.80
Input voltage [V]
3x400
Power output - P2 [kW]
22
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
41
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
this variant suits your choice
Maximum flow [l/min]
1,466
Maximum head [m]
95.50
Input voltage [V]
3x400
Power output - P2 [kW]
18.50
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
34
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
this variant suits your choice
Maximum flow [l/min]
1,466
Maximum head [m]
142.40
Input voltage [V]
3x400
Power output - P2 [kW]
30
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
53
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
this variant suits your choice
Maximum flow [l/min]
1,466
Maximum head [m]
125.30
Input voltage [V]
3x400
Power output - P2 [kW]
30
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
53
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
this variant suits your choice
Maximum flow [l/min]
1,466
Maximum head [m]
170.60
Input voltage [V]
3x400
Power output - P2 [kW]
37
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
65
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
this variant suits your choice
Maximum flow [l/min]
1,466
Maximum head [m]
153.50
Input voltage [V]
3x400
Power output - P2 [kW]
30
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
53
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
this variant suits your choice
Maximum flow [l/min]
1,466
Maximum head [m]
199.50
Input voltage [V]
3x400
Power output - P2 [kW]
45
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
78
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
this variant suits your choice
Maximum flow [l/min]
1,466
Maximum head [m]
181.70
Input voltage [V]
3x400
Power output - P2 [kW]
37
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
65
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
this variant suits your choice
Maximum flow [l/min]
1,466
Maximum head [m]
227.70
Input voltage [V]
3x400
Power output - P2 [kW]
45
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
78
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
this variant suits your choice
Maximum flow [l/min]
1,466
Maximum head [m]
210.60
Input voltage [V]
3x400
Power output - P2 [kW]
45
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
78
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage
this variant suits your choice

Product description

Construction

Vertical multistage pumps with suction and discharge ports of the same diameter. They are located in the same axis (in-line). Corrosion-resistant sliding bearings are lubricated with pumped liquid. Removal of the mechanical seal without the need to dismantle the engine (applies to MXV 50 and MXV 100 with engines with a power higher than 4 kW). The pump is equipped with an axial bearing and an enabling insert use of any standard engine in IM V1 design.

Use

  • For pumping water
  • For clean, non-explosive liquids without solid, fibrous or abrasive particles (adjustment of sealing materials on request).
  • Universal pump for domestic and industrial use, for pressure stations, fire extinguishing systems, high pressure washers, irrigation, for agriculture and sports equipment.

Operating conditions

  • Liquid temperature: from -15 °C to +110 °C (up to +120 °C for MXV 50).
  • Ambient temperature: up to 40 °C.
  • Maximum permissible pressure in the pump body: 25 bar. (16 bar for pumps with oval flanges).

Engine

  • Standard type: 2-pole asynchronous motor, 50 Hz (n ~ 2900 rpm). Construction IM V1 (EN 60034-7).
  • Motor suitable for operation with a frequency converter.
  • IE3 classification scheme for three-phase motors.
  • Insulation class F. Degree of protection IP 55.
  • Three-phase, nominal voltage: up to 3kW 230/400V
  •                                               from 4 kW 400/690 V.

Technical Specifications

Maximum flow [l/min]
1,466
Maximum head [m]
38.90 - 227.70
Input voltage [V]
3x400
Power output - P2 [kW]
15 - 45
Suction port ["]
DN100
Delivery port ["]
DN100
Maximum suction lift [m]
8
Maximum current [A]
14.30 - 78
Maximum liquid temperature [°C]
110
Protection [IP]
55
Automatic thermal protection
NO
Dry run protection
NO
Off switch
NO
Speed ​​control
NO
Capacitor
NO
Pump design
vertical
Impeller material
stainless steel
Construction
multi-stage